Eaton ePDU G3 Basic: unmetered power distribution
ePDU G3 Basic is Eaton’s unmetered tier: reliable outlets with a lightweight aluminium chassis, tool-less mounting and integrated IEC outlet grips to hold cords in place, without a display or network interface. Eaton’s own site restricts automated access to its full catalogue, so this page carries the two references we could source, EBAB08 and EBAB338.

Technical specification
| Model | Type | Input plug | Outlets | Current / voltage | Phase | Form factor |
|---|---|---|---|---|---|---|
| EBAB08 | Basic power distribution | IEC 60309 32A | (36) C13 + (6) C19 | 32 A, 200–240 V | Single-phase | Vertical, 0U |
| EBAB338 | Basic power distribution | – | – | 43.6 kW | – | Vertical, 0U |
Source of the values: Eaton ePDU G3 SKU specification pages, indexed via distributor product listings (eaton.com blocks automated access). Eaton’s own site blocks automated access; the values above come from distributor SKU pages that publish Eaton’s specification (see source list). EBAB338 is a large three-phase unit; only its power rating and dimensions were confirmed, other cells are blank rather than guessed. An en dash means the manufacturer does not publish that value; we do not fill it in with an estimate. Confirm every figure against the current manufacturer document before it is written into a contract.
The references we quote in this family are EBAB08 and EBAB338. Send us the load, the phase and the outlet count you need, and we will confirm availability and lead time.
Which one should you choose?
Integrated outlet grips solve a real cabling problem
IEC power cords work loose in a dense rack more often than the connector type suggests, and a single loose cord in a switched PDU can look like a device failure. The grip feature on ePDU G3 is a small mechanical detail that removes a recurring troubleshooting call.
EBAB08 and EBAB338 are very different scales
EBAB08 is a 32 A single-phase 0U unit with 36 C13 outlets, suited to a standard IT rack. EBAB338 is rated at 43.6 kW, a large three-phase distribution unit for a high-density row rather than a single rack. Confirm which scale your project actually needs before requesting a quote.
Basic is the right starting point for a straightforward rack
If the rack has one predictable load and no requirement for remote visibility, Basic avoids paying for monitoring and network features that would sit unused. Upgrading later to Metered Input or Managed is a straightforward like-for-like swap within the same ePDU G3 platform.
Tool-less mounting shortens a straightforward install even further
The pre-installed, tool-less mounting buttons on ePDU G3 mean a rack technician does not need to carry screws or a driver for a routine PDU swap, which sounds minor until you are doing it on the twentieth rack in a row during a deployment.
Side-mounting avoids fan and power supply interference
Optional side mounting button locations let the PDU sit at a 90-degree rotation without blocking hot-swap fans or power supplies on adjacent equipment, useful in a densely populated rack where the standard rear position is not free.
Where it fits, and where it does not
Fits a rack with a fixed, predictable load where reliable distribution matters more than visibility. Does not fit a shared or capacity-managed circuit; see Metered Input or Managed for that.
What we need in order to quote it
- Load in amps and whether single or three-phase
- Rack scale: single rack or a high-density row
- Outlet count and type needed
Request a Quote
Tell us the usable capacity, the protocol and the delivery country. A priced quote comes back within 48 hours, usually with a second option so the trade-off is visible.